42 lines
1.5 KiB
PHP
42 lines
1.5 KiB
PHP
<?php // phpcs:ignoreFile
|
|
$pageTitle = 'Steam Plant';
|
|
$metaDescription = 'Bagasse-fired boilers with scrubbers and ash handling keep the LASUCA factory running.';
|
|
$activeNav = 'factory';
|
|
require __DIR__ . '/../inc/theme-header.php';
|
|
?>
|
|
|
|
<main>
|
|
<header class="hero hero-sub">
|
|
<div class="container">
|
|
<span class="badge">Factory information</span>
|
|
<h1>Steam plant</h1>
|
|
<p>
|
|
Bagasse-fired boilers, natural gas backup, and ash handling systems provide reliable steam for every station.
|
|
</p>
|
|
</div>
|
|
</header>
|
|
|
|
<section class="page-section py-5">
|
|
<div class="container">
|
|
<div class="content-card">
|
|
<p>
|
|
The St. Martin steam plant features three 1,500 hp boilers (two with incline pinhole grates for bagasse
|
|
and one Detroit stoker), one 1,300 hp boiler with incline pinhole grates, and two 800 hp horseshoe-furnace
|
|
boilers.
|
|
</p>
|
|
<p>
|
|
Each boiler includes induced-draft fans, fly-ash removal linked to individual scrubbers, and air pre-heaters.
|
|
All units can switch to natural gas when required.
|
|
</p>
|
|
<p>
|
|
Ash removal relies on screw conveyors beneath the floor feeding slat conveyors that deliver material to a
|
|
centralized gathering tank outside the boiler room.
|
|
</p>
|
|